Isocyanates aerosols sampling for occupational exposures assessment
Publication
Current devices for sampling isocyanates do not allow the entire gaseous and particulate fraction to be sampled over 8 hours or require the use of an impinger not compatible with individual sampling. This presentation discusses the study of CIP 10-I for isocyanates sampling, the determination of the particle size distribution of isocyanates particles in companies, and the effectiveness of CIP 10-I on these particle size fractions.
-
Technical datasheet
-
Year of publication
2022 -
Language
Anglais -
Discipline(s)
Métrologie des expositions -
Author(s)
-
Reference
Proceedings AIRMON 2022 - 10th International Symposium on modern principles of air monitoring and biomonitoring, November 7-11, 2022, Bristol, United Kingdom
-